WNS type fuel (gas) steam boiler





WNS type fuel (gas) steam boiler content description:
WNS type fuel (gas) steam boiler is a horizontal fast-mounted internal combustion three-return fire tube boiler. The offset furnace bile wet-back structure is adopted, and the high-temperature flue gas sequentially flushes the second and third return smoke pipes, and then is discharged into the atmosphere from the rear smoke chamber through the chimney. The boiler is equipped with movable front and rear smoke box covers, making the boiler convenient for maintenance. The boiler is equipped with a technically good burner, which adopts advanced technologies such as automatic combustion proportional adjustment, automatic feed water adjustment, program start and stop, and fully automatic operation. . This type of boiler has the characteristics of compact structure, safety and reliability, easy operation, rapid installation, less pollution, low noise, high efficiency and so on.
WNS fuel oil (gas) steam boiler fuel: fuel oil, gas



main feature:
1. The overall structure is reasonable, compact, and belongs to the boiler island type, which meets the conditions of quick installation and delivery. This product is composed of three parts when it leaves the factory; the main engine of the boiler, chimney, and piping system, of which the main engine and chimney have been manufactured in the factory. Just assemble with the chimney. Connect the gas source, power supply and water pipeline on site to test run. Greatly shorten the installation cycle and ensure product quality.
2. Advanced design performance.
The main body of the boiler is an integrated structure. The burner is assembled on the front smoke box cover, and the body is mainly arranged with a heating surface and a combustion chamber part. The structure is reasonable and compact, and the consumption of steel is low. The furnace is made of offset wave furnace. The insulation layer is made of new lightweight thermal insulation materials. The outer packaging is made of colored sheets. Compared with domestic products with the same appearance, the appearance and appearance have obvious advancedness and aesthetic sense.
The boiler water supply equipment is arranged on the boiler base on the right side of the boiler so that it is integrated with the host without additional foundation.
3. The water circulation is simple, and the structure of the pressure parts is reasonable, and the water can be safely operated under the condition of ensuring the water quality.
4. Complete auxiliary equipment and advanced comprehensive technical performance.
The working process of the boiler:
The fuel enters the burner from the external gas source and generates high-temperature flames through automatic adjustment and automatic ignition. It enters the burn-out chamber from the front end of the furnace, enters the convection heating surface on the upper side of the rear of the burn-out chamber, and enters the second through the upper part of the front smoke box The convective heating surface leaves the boiler from the rear of the rear smoke box and is discharged into the atmosphere to the mast. If smoke and dust are generated due to improper air conditioning, they can be settled in the front and rear smoke boxes and the burn-out room, and the inspection doors can be opened for cleaning. The working fluid is heated to produce saturated steam, which is output to the operating system by the main steam valve.
WNS type fuel (gas) steam boiler protection device


1. Steam boiler water level real-time monitoring function: Equipped with electronic detection water level device to monitor the boiler water level in real time.
2. Steam boiler time setting function: Users can freely set the start and stop time of the boiler according to their needs.
3. Steam boiler leakage protection function: The control system will automatically cut off the power after detecting the leakage of the electric heating element.
4. Steam boiler water shortage protection: When the boiler lacks water, the burner control circuit is cut off in time to prevent burner damage and the controller issues a water shortage alarm indication.
5. Abnormal protection function of steam boiler power supply: The boiler stops operation immediately.
6. Steam boiler overpressure interlock protection: When the pressure inside the boiler exceeds the user set value, the burner is prohibited from working and an alarm is given.
7. Steam boiler pressure controller, water level alarm, safety valve, extremely low water level alarm and other multiple protections.
8. Complete gas valve group and protection system of steam boiler: Provide complete gas valve groups and accessories from filters, pressure regulators, solenoid valves, etc., to ensure the safety of gas.
9. Steam boiler flue gas monitoring device, which can automatically monitor the exhaust temperature of the boiler, and more easily grasp the combustion situation of the boiler.


【WNS Series Horizontal Fuel / Gas Steam Boiler—Technical Parameters】


model
WNS0.5-0.4 (0.8)
-Y (Q)
WNS0.75-0.4 (0.8)
-Y (Q)
WNS1-0.8 (1.0)
-Y (Q)
WNS1.5-1.0
-Y (Q)
WNS2-1.0
-Y (Q)
WNS3-1.25
-Y (Q)
project
parameter
Rated thermal power (MW)
0.5
0.75
1
1.5
2
3
Rated working pressure (MPa)
0.4 (0.8)
0.4 (0.8)
0.8 (1.0)
1.0
1.0
1.25
Outlet / backwater temperature (℃)
152 (175)
175 (184)
184
184
194
Design efficiency (%)
85% -92%
Water volume (m3)
1.2
1.56
2.10
2.7
2.7
5.9
Full water weight (t)
4.48 (5)
5.76 (6.2)
6.48 (7.1)
8 (8.4)
8 (8.4)
16 (16.8)
Power consumption (KW)
3.6
3.6
5.9
15.8
17.7
19.7
Power (V)
380
Applicable fuel
Light oil, natural gas, heavy oil, city gas, petroleum liquefied gas
Calculate consumption:
Light oil (kg / h)
Natural gas (m3 / h)
Heavy oil (kg / h)
City gas (m3 / h)
Petroleum liquefied gas (m3 / h)
34
41
35
92
14

51
62
53
138
20

65
82
70
184
26
102
123
105
276
39
136
164
140
368
52
204
246
210
552
79
Length × Width × Height (mm)
2650 × 1600
× 1700
2650 × 1600
× 1800
3650 × 1800
× 1800
5200 × 2300
× 2400
5200 × 2300
× 2400
5570 × 3200
× 2670
Installation size
Inlet / outlet valve diameter (mm)
50
65
65
65
65
100
Sewage valve diameter (mm)
40
40
40
40
40
40
Caliber of safety valve (mm)
40
2 × 40
2 × 40
2 × 50
2 × 50
2 × 65
Chimney diameter ф (mm)
250
300
320
360
360
360
:我们将尽可能地在本网站提供准确的信息。 ★ Note ★ : We will provide as accurate information as possible on this website. The pictures of the products involved in this website may be slightly different from the actual products. The effect diagrams and schematic diagrams are for reference only (some pictures are synthetic diagrams, simulation demonstration diagrams, and effect diagrams). The appearance of the Stone boiler products (including but not limited to) Color) Please prevail in kind. Product prices, specifications, models, and supply conditions are subject to change without notice.



model
WNS4-1.25
(1.6) -Y (Q)
WNS5 -1.25
(1.6) -Y (Q)
WNS6-1.25
(1.6) -Y (Q)
WNS8 -1.25
(1.6) -Y (Q)
WNS10 -1.25
(1.6) -Y (Q)
WNS15 -1.25
(1.6) -Y (Q)
WNS20 -1.25
(1.6) -Y (Q)
project
parameter
Rated thermal power (MW)
4
5
6
8
10
15
20
Rated working pressure (MPa)
1.25 (1.6)
Outlet / return water temperature (℃)
194 (204)
Boiler design efficiency (%)
85% -92%
Water volume (m3)
7.14
10
10.2
13.9
16.7
30
30
Full water weight (t)
22 (23.5)
24.7 (26)
25.5 (26.5)
32.5 (34.5)
38 (42)
74 (78)
78 (82)
Power consumption (KW)
22.2
34.4
34.4
36
36
72
72
Power (V)
380
Applicable fuel
Light oil, natural gas, heavy oil, city gas, petroleum liquefied gas
Calculate consumption:
Light oil (kg / h)
Natural gas (m3 / h)
/ Heavy oil (kg / h)
City gas (m3 / h)
Petroleum liquefied gas (m3 / h)
272
328
280
736
105
241
413
352
922
131
382
429
377
972
139
482
429
377
972
139
603
715
628
1620
231
904
1075
942
2430
347
1206
1430
1256
3240
462
Length × Width × Height (mm)
5600 × 3300
× 2880
6020 × 3300
× 3060
7200 × 3300
× 3060
7300 × 3300
× 3060
7400 × 3300
× 3060
8100 × 4200
× 4100
8500 × 4500
× 4100
Installation size
Inlet / outlet valve diameter (mm)
100
125
125
150
150
200
200
Sewage valve diameter (mm)
2 × 40
2 × 40
2 × 40
2 × 40
2 × 40
2 × 40
40
Caliber of safety valve (mm)
2 × 50
50 × 80
50 × 80
2 × 80
2 × 80
2 × 80
2 × 100
Chimney diameter ф (mm)
530
530
530
680
380
1000
1200
:我们将尽可能地在本网站提供准确的信息。 ★ Note ★ : We will provide as accurate information as possible on this website. The pictures of the products involved in this website may be slightly different from the actual products. The effect diagrams and schematic diagrams are for reference only (some pictures are synthetic diagrams, simulation demonstration diagrams, and effect diagrams). The appearance of the Stone boiler products (including but not limited to) Color) Please prevail in kind. Product prices, specifications, models, and supply conditions are subject to change without notice.






  • No more articles
  • No more articles
  • © 2018 Henan Sitong Boiler Co., Ltd. All rights reserved
    24-hour consultation hotline:
    13673423999
    online service